Skip to content
Logitots

HVAC Fans — Product Family

Belt-Drive Fans

Belt-driven arrangements where pulley ratios allow the duty to be adjusted on site.

Retrofit and variable duty installations
Belt-driven centrifugal HVAC fan on a steel base frame in a mechanical room

Applications

Retrofit and variable duty installations

  • Air handling units
  • Central air conditioning
  • Ducted ventilation
  • Packaged HVAC plant
  • Terminal equipment

Key features

  • Adjustable pulley ratios
  • Motor separated from the airstream

Configurations

  • Arrangement 1
  • Arrangement 9
  • Arrangement 10

Documents

  • Technical datasheetAvailable on request
  • Dimensional drawingAvailable on request
  • Performance curveAvailable on request
  • Wiring / control diagramAvailable on request
Request a Quote
Technical Specifications

Reference technical ranges

Representative ranges for equipment sourced in this category. Selection is confirmed against the submitted duty point.

SYP — Double-Inlet Forward-Curved Centrifugal Fan

Product type
Double-inlet forward-curved centrifugal fan
Impeller diameter
130–270 mm
Air volume
250–3,000 m³/h
Static pressure
Up to 400 Pa
Drive type
Direct
Application
Central air-conditioning and ventilation systems

SYZ — Double-Inlet Forward-Curved Centrifugal Fan

Product type
Double-inlet forward-curved centrifugal fan
Air volume
800–5,000 m³/h
Static pressure
Up to 500 Pa
Drive type
Direct
Application
Central air-conditioning and air-handling systems

SYB — External-Rotor Direct-Drive Centrifugal Fan

Product type
External-rotor direct-drive centrifugal fan
Impeller diameter
200–500 mm
Air volume
1,000–20,000 m³/h
Static pressure
Up to 600 Pa
Drive type
Direct
Application
HVAC and air-handling equipment

SYBS — External-Rotor Direct-Drive Centrifugal Fan

Product type
External-rotor direct-drive centrifugal fan
Impeller diameter
180–400 mm
Air volume
1,000–8,000 m³/h
Static pressure
Up to 500 Pa
Drive type
Direct

SYT — Double-Inlet Forward-Curved Centrifugal Fan

Product type
Double-inlet forward-curved centrifugal fan
Impeller diameter
7–30 in
Air volume
1,000–50,000 m³/h
Static pressure
Up to 800 Pa
Drive type
Belt

SYD — Double-Inlet Forward-Curved Centrifugal Fan

Product type
Double-inlet forward-curved centrifugal fan
Impeller diameter
180–1,000 mm
Air volume
1,000–100,000 m³/h
Static pressure
Up to 1,300 Pa
Drive type
Belt

Technical specifications shown are representative reference ranges and may vary by model, configuration, manufacturer and application. Final specifications should be confirmed against the applicable product datasheet.